Technical specs

s7

Features S7

  • Configurable analogue front end to support different types of transducers
  • Adjustable threshold and value alarms
  • Adjustable measurement interval
  • RSSI and LQI diagnostics
  • Long life battery design
  • Battery monitoring
  • Encrypted data transmission
  • Remote configuration via R7
  • Factory set 64-bit identifier
  • Easy to set-up

Operating Specifications

Enclosure:IP67
Ambient temperature:-25…+55°C
Vibration:Tested according to IEC60770-1

Regulatory Compliance Statement

Hazardous location certificates:ATEX/IECEx certified to II 2G Ex ib IIC T4
EMC conformity standards:EN61326 Class A
R&TTE conformity standards:ETSI EN 300 328 ETSI EN 301 489-17 EN61010-1
Regulation conformity of the wireless model:FCC approval, IC approval
r7-mitat1-640x549

Features R7

  • Multiple network infrastructures supported
  • Internal diagnostics
  • Communications diagnostics, RSSI and LQI
  • Sensor network data storage in case that data transmission is lost
  • Change and transmit of new calibration files of transducers to S7 units
  • Easy to set-up

Wired communication interface

Ethernet:10/100 Base-TX
Serial communication:2 x RS-485
Communication protocol:Creowave proprietary, other protocols on request

Regulatory Compliance Statement

Hazardous location certificates:ATEX/IECEx certified II 2G Ex mb (ib) IIC T4
EMC conformity standards:EN61326 Class A
R&TTE conformity standards:ETSI EN 300 328 ETSI EN 301 489-17 EN 61010-1
Regulation conformity of the
wireless model:
FCC approval, IC approval

Datasheet Download